Technical Specification : |
|
| |
VDRM/VRRM Range x100
(V) |
IT(av)/Tc
(A) |
null
(0C) |
IT(RMS)
(A) |
ITSM 10ms Tj1x
(A) |
I2T 10ms A211
(AX103) |
IDRM & IRRM
(mA) |
Vo (Typ)
(V) |
r (Typ)
(mW) |
Vpeak/Ipeak Tj 1x
(V) |
null
(A) |
Tj 1x
(0C) |
Rth(j-c) Sin1800
(0C/W) |
Rth(c-h)
(0C/W) |
IGT/VGT at 250C
(mW) |
PGpeak Pulse 14idth 10010
(W) |
VFGM
(V) |
IFGM
(A) |
IL
(mA) |
di/dt REP
(A/mS) |
Tq
(mSec) |
QRR at dir/dt=20 6ec
|
Reapplied dv/dt
(V/mSec) |
14t.
(gms) |
| 2-12 |
120 |
85 |
190 |
2900 |
42 |
30 |
1.2 |
1.6 |
2.2 |
500 |
125 |
0.2 |
0.08 |
150/2.5 |
40 |
12 |
10 |
1000 |
160 |
20-25 |
75 |
D,F |
320
|
|
|
| |
|
|
| |
Formulae
: |
|
| |
- The
power loss of the device :-
- PW
= V0 X IF(AV) + (IRMS)(IRMS) X r
- V0
= Threshold Voltage
- IF(AV)
or IT(AV) =Average Forward Current
- IRMS
= IF(AV) X Form Factor
- r
= Slope resistance in Ohms
- Form
Factor for :-
- Half
Sine Wave 1800 Conduction=1.57
- 3
Phase 1200 Conduction =1.74
- 6
Phase 600 Conduction =2.44
- Heat
Sink Thermal Resistance Rth H-A:-
- Tj
=TA +PW [Rth(J-C) +Rth(C-H) + Rth(H-A)]
- TA
= Ambient Temperature.
|
|
|
|